Solar Variable Frequency Drives IP20 was specially designed for solar water pumping applications.
Solar Variable Frequency Drives IP20 was specially designed for solar water pumping applications.
1 Phase 220V output |
||||
Series |
-SS2 Series |
|||
AC input voltage (V) |
220(-15%)~240(+10%) (1PH) |
|||
Max input DC voltage (V) |
440 |
|||
Starting voltage (V) |
200 |
|||
Min operating voltage (V) |
150 |
|||
Recommended DC input voltage range |
200~400 |
|||
Recommended MPP voltage (V) |
330 |
|||
Rated output voltage (V) |
1PH 220 |
|||
Output frequency range (Hz) |
0~400 |
|||
MPPT |
99% |
|||
Installation mode |
Support wall-type, rail-type and flange-type installation |
|||
Ambient temp |
-10°C~+50°C, derate by 2% per every additional 1°C if the temp is above |
|||
Elevation |
Below 1000m; derate by 1% per every additional 100m if the elevation is above 1000m |
|||
Cooling mode |
Air cooling |
|||
Rated parameters: |
||||
Series |
Model |
Rated output
power |
Rated input
current |
Rated output
current |
-SS2 series
1PH 220V
input/output
(0.4-2.2 kW)
|
GD100-0R4G-SS2-PV |
0.4 |
6.5 |
4.2 |
GD100-0R7G-SS2-PV |
0.75 |
9.3 |
7.2 |
|
GD100-1R5G-SS2-PV |
1.5 |
15.7 |
10.2 |
|
GD100-2R2G-SS2-PV |
2.2 |
24 |
14 |
3 Phase 220V output |
||||
Series |
-S2 Series |
-2 Series |
||
AC input voltage (V) |
220(-15%)~240(+10%) (1PH) |
220(-15%) ~240(+10%) (3PH) |
||
Max input DC voltage (V) |
440 |
440 |
||
Starting voltage (V) |
200 |
200 |
||
Min operating voltage (V) |
150 |
150 |
||
Recommended DC input voltage range |
200~400 |
200~400 |
||
Recommended MPP voltage (V) |
330 |
330 |
||
Rated output voltage (V) |
3PH 220 |
3PH 220 |
||
Output frequency range (Hz) |
0~400 |
|||
MPPT |
99% |
|||
Installation mode |
Support wall-type, rail-type and flange-type installation |
|||
Ambient temp |
-10°C~+50°C, derate by 2% per every additional 1°C if the temp is above |
|||
Elevation |
Below 1000m; derate by 1% per every additional 100m if the elevation is above 1000m |
|||
Cooling mode |
Air cooling |
|||
Rated parameters: |
||||
Series |
Model |
Rated output
power |
Rated input
current |
Rated output
current |
-S2 Series
1PH 220V input
3PH 220V
output
(0.4-2.2 kW)
|
GD100-0R4G-S2-PV |
0.4 |
6.5 |
2.5 |
GD100-0R7G-S2-PV |
0.75 |
9.3 |
4.2 |
|
GD100-1R5G-S2-PV |
1.5 |
15.7 |
7.5 |
|
GD100-2R2G-S2-PV |
2.2 |
24 |
10 |
|
-2 Series
3PH 220V
input/output
(4-7.5kW)
|
GD100-004G-2-PV |
4 |
17 |
16 |
GD100-5R5G-2-PV |
5.5 |
25 |
20 |
|
GD100-7R5G-2-PV |
7.5 |
33 |
30 |
3 Phase 380V output |
||||
Series |
-4 Series |
|||
AC input voltage (V) |
380(-15%) ~440(+10%) (3PH) |
|||
Max input DC voltage (V) |
800 |
|||
Starting voltage (V) |
300 |
|||
Min operating voltage (V) |
250 |
|||
Recommended DC input voltage range |
300~750 |
|||
Recommended MPP voltage (V) |
550 |
|||
Rated output voltage (V) |
3PH 380 |
|||
Output frequency range (Hz) |
0~400 |
|||
MPPT |
99% |
|||
Installation mode |
Support wall-type, rail-type and flange-type installation |
|||
Ambient temp |
-10°C~+50°C, derate by 2% per every additional 1°C if the temp is above |
|||
Elevation |
Below 1000m; derate by 1% per every additional 100m if the elevation is above 1000m |
|||
Cooling mode |
Air cooling |
|||
Rated parameters: |
||||
Series |
Model |
Rated output
power |
Rated input
current |
Rated output
current |
-4 Series
3PH 380V
input/output
(0.75-110kW)
|
GD100-0R7G-4-PV |
0.75 |
3.4 |
2.5 |
GD100-1R5G-4-PV |
1.5 |
5 |
4.2 |
|
GD100-2R2G-4-PV |
2.2 |
5.8 |
5.5 |
|
GD100-004G-4-PV |
4 |
13.5 |
9.5 |
|
GD100-5R5G-4-PV |
5.5 |
19.5 |
14 |
|
GD100-7R5G-4-PV |
7.5 |
25 |
18.5 |
|
GD100-011G-4-PV |
11 |
32 |
25 |
|
GD100-015G-4-PV |
15 |
40 |
32 |
|
GD100-018G-4-PV |
18.5 |
47 |
38 |
|
GD100-022G-4-PV |
22 |
56 |
45 |
|
GD100-030G-4-PV |
30 |
70 |
60 |
|
GD100-037G-4-PV |
37 |
80 |
75 |
|
GD100-045G-4-PV |
45 |
94 |
92 |
|
GD100-055G-4-PV |
55 |
128 |
115 |
|
GD100-075G-4-PV |
75 |
160 |
150 |
|
GD100-090G-4-PV |
90 |
190 |
180 |
|
GD100-110G-4-PV |
110 |
225 |
215 |
Boost module for 0.4 - 2.2KW |
|
0.4-2.2kW models can be configured with the boost module, which can improve the utilization of the solar component. |
|
Model |
PP100-3R2-PV |
Input |
|
Max. input power (W) |
3200 |
Max. DC voltage (V) |
600 |
Start-up voltage (V) |
80 |
Min. working voltage (V) |
70 |
Max. input current (A) |
12 |
Output |
|
Output voltage (V) |
350/570 (automatically determined by the inverter) |