The smart micro grid structure demands different for different load, but the basic unit containing distributed power (energy), energy storage device, and load management system. Most interface of the micro energy to the grid requirements is designed based on power electronic technology, to ensure the micro grid to run flexibility and reliability as a single system.
Micro grid system with interconnection and independent (isolated) two stable operation condition and two corresponding transition state: on grid state and micro grid solution.
The smart micro grid structure demands different for different load, but the basic unit containing distributed power (energy), energy storage device, and load management system. Most interface of the micro energy to the grid requirements is designed based on power electronic technology, to ensure the micro grid to run flexibility and reliability as a single system.
Micro grid system with interconnection and independent (isolated) two stable operation condition and two corresponding transition state: on grid state and micro grid solution.
Type |
SX10KS |
SX20KS |
SX50KS |
SX100KS |
SX250KS |
SX500KS |
SX1000KS |
SX1500KS |
AC side parameter |
||||||||
Capacity |
10kW |
20kW |
50 kW |
100 kW |
250kW |
500kW |
1000kW |
1500kW |
Overload |
11kW |
22 kW |
55 kW |
110 kW |
275kW |
550kW |
1100kW |
1650kW |
On-grid charge and discharge mode |
||||||||
Grid rated voltage |
220Vac/380 Vac/480Vac(Optional) |
|||||||
Grid voltage range |
±20%Un |
|||||||
Grid frequency range |
50Hz/60Hz |
|||||||
(THD) |
<3% |
|||||||
PF |
≥0.99 |
|||||||
Independent on grid mode |
||||||||
Rated output voltage |
220 Vac/380 Vac |
|||||||
Output voltage distortion |
<3% |
|||||||
Output frequency |
50Hz/60Hz |
|||||||
Output over voltage protection |
>120%Un |
|||||||
Output under protection |
<80%Un |
|||||||
DC Voltage range |
||||||||
Max DC power |
11kW |
22 kW |
55 kW |
110 kW |
275kW |
550kW |
1100kW |
1650kW |
DC voltage range |
450-750Vdc, opptional according to the customer need |
|||||||
Dc current ripple |
<5% |
|||||||
System |
||||||||
Max conversion efficiency |
96.60% |
|||||||
Working Enviroment |
-25 ~ +50°C |
|||||||
Relative humidity |
0~95%, non-condensing |
|||||||
Noise |
<65dB |
|||||||
Defensive function |
Possess the protecting function of polarity connecting contrary,short circuit, island effects ,over heat, over load, ground fault |
|||||||
Cooling way |
Forced air |
|||||||
Protect degree |
IP20 |
|||||||
Display and communication |
||||||||
Display |
Touch screen |
|||||||
Standard Commnicaiton |
RS485 (MODBUS protocol) |